1. I do Heat Load calculation in an excel sheet and derive the tonnage for the area to be airconditioned.
2. Do Duct design and Chilled water pipe design with Mcquay sizer software.
3. And do VRV/VRF...
Read more
1. I do Heat Load calculation in an excel sheet and derive the tonnage for the area to be airconditioned.
2. Do Duct design and Chilled water pipe design with Mcquay sizer software.
3. And do VRV/VRF design with pipe routings.
4. Convert the design into Autocad 2D drawings as per the requirements.
5. Additionally I do Data Entry work in which I can convert any file format to MS word with reasonable speed and accuracy.
We, ITS MADE EZY, have been handling creative mechanical design and product design projects using the software such as SOLIDWORKS for 3d modeling and ANSYS for analysis. Also we have much experience...
Read more
We, ITS MADE EZY, have been handling creative mechanical design and product design projects using the software such as SOLIDWORKS for 3d modeling and ANSYS for analysis. Also we have much experience by making real world components into 3d models, analysed them and have made tutorials to help people learn MECHANICAL CAD.
we are also handling Architectural 2D & 3D Design projects using AutoCAD and Sketchup. We use Lumion and V-ray for Rendering Services.
We have our own YOUTUBE CHANNEL named ITS MADE EZY that covers tutorials for mechanical design software like SOLIDWORKS, CATIA, CREO, FUSION 360, ANSYS WORKBENCH.
Our YouTube channel, for your kind information,
YouTube: It's made ezy
To know more about us, kindly visit our page.
We would feel proud to be a part of your project works by giving SATISFACTION BEYOND your EXPECTATION.
Looking forward to get in touch you.
Thanks.
1. I do Heat Load calculation in an excel sheet and derive the tonnage for the area to be airconditioned.
2. Do Duct design and Chilled water pipe design with Mcquay sizer software.
3. And do VRV/VRF...
Read more
1. I do Heat Load calculation in an excel sheet and derive the tonnage for the area to be airconditioned.
2. Do Duct design and Chilled water pipe design with Mcquay sizer software.
3. And do VRV/VRF design with pipe routings.
4. Convert the design into Autocad 2D drawings as per the requirements.
5. Additionally I do Data Entry work in which I can convert any file format to MS word with reasonable speed and accuracy.