I will run data hall airflow CFD and deliver an ASHRAE thermal report

Request a service

Small Data Room Airflow CFD
Single room up to ~30 racks; 2 scenarios (normal + one cooling-unit failure). ASHRAE inlet check, hotspot list, plots, recommendations. PDF report. 1 revision.

7-day delivery

1 revisions

Dry Cooler Yard Recirculation CFD
Up to ~12 dry coolers/condensers; multi-wind-direction recirculation; inlet temperature rise per unit; 2 mitigation options compared. PDF report. 1 revision.

10-day delivery

1 revisions

Waste Heat Recovery Pre-Feasibility
One heat source + one reuse option: available heat, simple payback, assumptions list. Tables + brief. 1 revision.

5-day delivery

1 revisions


Request customized services

If this service doesn’t quite match your needs, reach out for a custom quote. Discuss pricing and deadlines to design a project just for you.

About this service

I run airflow and thermal CFD for data halls / server rooms and deliver an actionable engineering report.

Scope (fixed-rate package):
- Single data room, up to ~30 racks
- 2 scenarios: normal operation + one CRAH/CRAC failure (N+1)
- Rack inlet temperatures vs ASHRAE ranges, hotspot list, airflow/temperature plots
- Raised-floor / aisle-containment recommendations where relevant

You provide: layout (CAD/PDF) and equipment data. I confirm scope and assumptions in writing before starting.

Note: design-stage engineering analysis — not stamped/certified PE reports. One revision included; extra racks/scenarios quoted separately.
I run airflow and thermal CFD for data halls / server rooms and deliver an actionable engineering report.

Scope (fixed-rate package):
- Single data room, up to ~30 racks
- 2 scenarios: normal operation + one CRAH/CRAC failure (N+1)
- Rack inlet temperatures vs ASHRAE ranges, hotspot list, airflow/temperature plots
- Raised-floor / aisle-containment recommendations where relevant

You provide: layout (CAD/PDF) and equipment data. I confirm scope and assumptions in writing before starting.

Note: design-stage engineering analysis — not stamped/certified PE reports. One revision included; extra racks/scenarios quoted separately.
I run airflow and thermal CFD for data halls / server rooms and deliver an actionable engineering report.

Scope (fixed-rate package):
- Single data room, up to ~30 racks
- 2 scenarios: normal operation + one CRAH/CRAC failure (N+1)
- Rack inlet temperatures vs ASHRAE ranges, hotspot list, airflow/temperature plots
- Raised-floor / aisle-containment recommendations where relevant

You provide: lay... read more
I run airflow and thermal CFD for data halls / server rooms and deliver an actionable engineering report.

Scope (fixed-rate package):
- Single data room, up to ~30 racks
- 2 scenarios: normal operation + one CRAH/CRAC failure (N+1)
- Rack inlet temperatures vs ASHRAE ranges, hotspot list, airflow/temperature plots
- Raised-floor / aisle-containment recommendations where relevant

You provide: layout (CAD/PDF) and equipment data. I confirm scope and assumptions in writing before starting.

Note: design-stage engineering analysis — not stamped/certified PE reports. One revision included; extra racks/scenarios quoted separately. read less

Service offer categories

Computational Fluid Dynamics 3D Design Services 3D Modeling

Software & skills

3D Design DESIG Design 3D Thermal Analysis design +2 more

This service includes

Service tiers Simple $480 Standard $900 Advanced $350
Summary Small Data Room Airflow CFD Dry Cooler Yard Recirculation CFD Waste Heat Recovery Pre-Feasibility
Details Single room up to ~30 racks; 2 scenarios (normal + one cooling-unit failure). ASHRAE inlet check, hotspot list, plots, recommendations. PDF report. 1 revision. Up to ~12 dry coolers/condensers; multi-wind-direction recirculation; inlet temperature rise per unit; 2 mitigation options compared. PDF report. 1 revision. One heat source + one reuse option: available heat, simple payback, assumptions list. Tables + brief. 1 revision.
Delivery time 7 days 10 days 5 days
Number of revisions 1 1 1
Chengdu, Sichuan, China – 2:36 a.m. local time

Member since
October 2026
Languages
Chinese, English
Avg. response time
1 hour

Data Center & Cooling CFD Engineer | Airflow and Thermal Simulation

I am a thermal engineer specialising in data center cooling, dry coolers and heat rejection. I run airflow and thermal CFD with 6SigmaDCX (Cadence Reality DC) and in-house tools, and I write reports that an engineer or a building owner can act on.

What I typically deliver:
- Data hall / server room airflow CFD: rack inlet temperatures vs ASHRAE ranges, hotspot list, aisle-containment recommendati... read more
Request a service

Small Data Room Airflow CFD
Single room up to ~30 racks; 2 scenarios (normal + one cooling-unit failure). ASHRAE inlet check, hotspot list, plots, recommendations. PDF report. 1 revision.

7-day delivery

1 revisions

Dry Cooler Yard Recirculation CFD
Up to ~12 dry coolers/condensers; multi-wind-direction recirculation; inlet temperature rise per unit; 2 mitigation options compared. PDF report. 1 revision.

10-day delivery

1 revisions

Waste Heat Recovery Pre-Feasibility
One heat source + one reuse option: available heat, simple payback, assumptions list. Tables + brief. 1 revision.

5-day delivery

1 revisions


Request customized services

If this service doesn’t quite match your needs, reach out for a custom quote. Discuss pricing and deadlines to design a project just for you.

Cad Crowd Billing Security policy

Service quality is protected by Cad Crowd Billing Security policy.