#4 Engineering design: extending foundation pile support by Ghufran Ahmed Farooqui
attached are the required stuff,
3D model IGES
DETAILED manufacturing drawings with BOQ & Exploded diagram
E- drawing
video opening closing from various views
please feel free to ask any thing you want, or any changing required.
thank you.
more
Dec 25, 2019 20:37
#1 CAD modeling of assy by Ghufran Ahmed Farooqui
hi mark, i have attached the model's E-drawing. please check it and if there is any issue so let me know. after that i will generate its animation and exploded view as well.
waiting for your responce
thank you
more
Dec 20, 2019 11:27
#24 CAD modeling of assy by Ghufran Ahmed Farooqui
final model as per changes is attached. i.e SW18 model files, IGES, video .
more
Jan 19, 2020 16:25

Discussion

Sat, 08 Feb 2020 15:29:10 +0000
i am glad that you liked my work, i would love to work with you in near future.

thank you
Regards: Ghufran

Mark Henry

Buyer

Thu, 06 Feb 2020 22:42:05 +0000
Hi Ghufran,Apolgoeis for not responding sooner, I had missed the messages.
Currently reviewing designs with my team. We will award winner tomorrow.
Your work has been very good so I would definately like to use you again.
Regards, Mark
Wed, 22 Jan 2020 11:20:27 +0000
Please check entry
Wed, 22 Jan 2020 11:20:24 +0000
Please check entry
Fri, 03 Jan 2020 13:59:03 +0000
yes, arms will be encapsulated inside the leg along with the CYL, thats why i was asking the Cyl dia to incorporate it the design.
Fri, 03 Jan 2020 13:54:17 +0000
yes pin's dia can be upsized, according to my calculations, it will be having factor of safety of ~2 if we make them 75mm. but i will make 60mm if you have calculated. secondly can you share hydraulic Cyl's full extended length & dead length so i can adjust the distances to ensure proper angles at opening and closing. i have a point that, arms should not be completely parallel to each other while closing (closed against pipe body) if that happens arms might lock against each other. so it should be kept at some angle can be placed if i know the full extended length of cyl.
and can you please open the message panel so i can explain stuff using images it will be convenient.

thanks

Ghufran

Mark Henry

Buyer

Fri, 03 Jan 2020 13:23:44 +0000
Hi Ghufran,
The arms need to support on both sides of the pins, not just 1 as currently shown. Otherwise they will bend and fail when piston is extended.
The pins all need to be upsized to 60mm diameter -due to updated loading calculations performed.
Regards,

Mark

Mark Henry

Buyer

Fri, 03 Jan 2020 12:49:49 +0000
Hi Ghufran,
Your redesigned arms looks better, will they fold inside each other when collapsed?
Also is it possible to upsize all the pins in the moving parts to 60 mm diameter, as calculations performed indicate current size may fail.
The hydraulic piston should be dimensioned to fit inside the arms when fully retracted (closed against pipe body).
When the hydraulic piston is at full extended stroke, the connecting arms should be locked out straight, with the main legs at 45 deg as per you schematic. When the piston retracts, the arms should fold up.
There is flexibility in the design if needed to make everything fit - so you can adjust the distance between clamps by +- 40cm if required.
Thanks,
Mark
Mon, 30 Dec 2019 13:26:07 +0000
can you share the cyl dimensions it will be help full to adjust distances

Mark Henry

Buyer

Mon, 30 Dec 2019 11:01:12 +0000
Hi Ghufran,
Thanks for the schematics, good job!
The parts for the arms (no 5) in the BOQ, need to be redesigned, the pins connecting need to be encapsulated so the structure is more stable, as the pistons will apply up to 50 Tons of force to extend the arms.

Thanks,

Mark