Description:
Need a structural steel design for a 40’x40’x 12’ high podium to support a 2 story wood frame house. Metal deck on c purlins and 3” concrete to be poured on metal deck. Prefer columns spacing of 20’.
Wants:
Functional and cost effective Need steel types and sizes
Don't Wants:
No bar joists.
Ask for Sample:
PDF only
Entries
1st Winner
#8 Podium StructuresR1
by meet855
Download Files
#1 Industrial hall
by Paskalovski
#2 Steel Constructions
by behxheth
Download Files
#4 steel podium
by tawandak
Download Files
#5 Podium Structures
by meet855
Download Files
#6 Steel podium
by tawandak
Download Files
#7 Steel Constructions - 40'x40' podium steel construction
by behxheth
Download Files
- Autodesk Inventor 2020 — W-135. 40x40x12
- Autodesk Inventor 2020 — 2.40 x40 steel podium-1
- Autodesk Inventor 2020 — 40 x40 steel podium
- Autodesk Inventor 2020 — 12.W-137
- Autodesk Inventor 2020 — 11.w-136
- Autodesk Inventor 2020 — 10.Plate Sharp Corners in 1635622152611
- Autodesk Inventor 2020 — 9.ANSI L 3 x 3 x 1 4 1635620236685
- Autodesk Inventor 2020 — 8.ANSI L 3 x 3 x 1 4 1635620159494
- Autodesk Inventor 2020 — 7ANSI HP10 x 57 1635616439229
- Autodesk Inventor 2020 — 5.ANSI HP10 x 57 1635616478534
- Autodesk Inventor 2020 — 4.ANSI HP10 x 57 1635616568541
- Autodesk Inventor 2020 — 3.ANSI HP10 x 57 1635616648069
- Autodesk Inventor 2020 — 1.40 x40 steel podium
Discussion
A simple pdf with material sizes and types will be fine
which format I have to submit (.blend, .stl or .obj)? thanks
Welded please.
For connecting between steel structures you prefer a bolted or welded system
I added an attachment that shows what the house will look like. It is wood framed .
Thanks
Thanks
I'd like to see the design of the house prior to considering making such a thing. If your house fits art deco, then the framing needs to be art deco, if it's modern it needs to be modern.
Kindly provide the Sample please.
Added sketch to project
Thanks
Thanks
Thanks for prepaid.
Can you please share any architect plan or elevation you make for this design?
Can you please share any architect plan or elevation you make for this design?
It is now pre paid
Prepaid please
sample
Prepaid please
Similar Contests on Cad Crowd
MBS Tekla Design For Steel Buildings Manufacturer
Hi,
We are a steel building manufacturer and need a freelancer to do our MBS and Tekla designs for Engineering and fabrication. We are based in the united states.
Thanks!
https://www.google.com/search?gs_ssp=eJzj4tVP1zc0TKkoNEy2NEtTYDRgdGDwksxNLUnMyclMVkgqzcxJycxLV0jOzy1IzKsEADi3Dro&q=metallic+building+company&rlz=1C1CHBF_enUS916US916&oq=metallic+&aqs=chrome.1.69i57j46i20i199i263i465i512j0i433i512l2j0i67j69i61j69i60j69i61.4919j0j7&sourceid=chrome&ie=UTF-8
Automatic Chicken Coop Door Opener
Design an automatic chicken coop door opener, to avoid those mechanical structures that are currently sold in the market, design a novel and unique product.
Low-Voltage Switchgear Cabinet for a Heating System in Accordance with DIN EN 61439
A complete low-voltage switchgear cabinet—including full documentation—is required for a medium-sized heating system (2 heating circuits, 1 boiler, 1 domestic-hot-water storage tank). All design work must be carried out exclusively in WSCAD and will be awarded as a remote.
DIN EN 61439-2 – Low-voltage switchgear and controlgear assemblies
EN 12828 – Heating systems in buildings
Low-Voltage Directive 2014/35/EU
Custom High Performance Electric Car
Dual-seat, electric hyper-car (4 × electric motors, 1 per wheel) aiming for 0-100 km h-¹ in ‹0.9 s. Fan-assisted ground-effect tunnels and full ADR-compliant street legality in Australia.
Alternative electric motor configurations will be considered so long as acceleration requirement is met.
Must satisfy all current 3rd-edition Australian Design Rules (ADR) applicable to MA-class passenger cars, incl. ADR 29/35 (side & frontal impact), ADR 42 (general safety), ADR 79/04 (Euro-6d emissions equivalent for EVs), ADR 82 (battery safety under crash / immersion)
Required deliverables:
1. Exterior Class-A surfaces (STEP or IGES + native file). 2. Battery & component packaging layout: plan, side & section views showing pack location, HV conduit routing, crush zones, occupant cell & suspension hard-points.
3. Under-floor aero scheme (intakes → fan plenum → diffuser) with airflow arrows.
4. Eight photorealistic renders & a 2-page design-rationale PDF explaining how ADR clearances, visibility cones, and e-safety rules are met.
• Quick CFD screenshot (pressure map) • 15 s animation
• ADR compliance checklist table referencing rule numbers.
File formats – STEP (.stp) or IGES (.igs), renders ≥ 3840 px.
construction bid specification, estimates, qs, mqs, nrm 2, boq, qto, sow, ost
Quantity Surveying and Design
Assist Project Study, Design of Solutions, plans and estimation Accurate QS, BOQ, RFQ,
Prepaid Prize
PK Lake Services
Buyer